Well Pump Not Working: Step-by-Step Troubleshooting
When a well pump is not working, start at the breaker and work toward the well: power, pressure switch, control box, tank, and only then the pump itself. Many dead pumps turn out to be a tripped breaker, a burned switch contact or a failed capacitor, all of which are fixed above ground.
The trick is to sort the failure by what the pump is doing. Silent, humming, running with no water, and clicking on and off each point somewhere different.
Step 1: Figure out what the pump is doing
Go to the tank, open a faucet and listen.
| What you notice | Where to look first |
|---|---|
| Nothing at all, gauge falls and pump never starts | Power, pressure switch, low-pressure cutoff |
| Motor hums or buzzes but doesn't run | Voltage, capacitor, control box, binding pump |
| Pump runs but little or no water | Prime, check valve, worn pump, low well |
| Pump clicks on and off every few seconds | Pressure tank, leak, switch |
| Breaker trips when the pump starts | Wiring, splice, motor, capacitor |
WAYNE and Goulds sort their own troubleshooting tables the same way. If you have a constant pressure drive with a display, read the code first; the fault code step below covers it.
Step 2: Check the power
Find the pump breaker. If it's off or in the middle, reset it once. Both WAYNE and Goulds list a tripped breaker or blown fuse as a cause of a pump that won't start.
If it trips again right away, stop and leave it off. A breaker that won't hold points to a short. Our page on a well pump that keeps tripping the breaker covers what comes next. Also check for a separate disconnect switch near the tank or well, which people bump with boxes.
Step 3: Check the pressure switch
With the power off, take the cover off the switch.
- Is there a lever on the side? That's a low-pressure cutoff. Boshart explains that some switches shut off the pump when pressure falls about 10 psi below cut-in. Lift and hold the lever while someone turns the breaker on. If the pump starts and pressure builds, let go once it passes cut-in. See resetting a low-pressure cutoff switch.
- Are the contacts burned or pitted? Black, pitted contacts may not close anymore. WAYNE lists a faulty pressure switch as a reason a pump won't start. Replace the switch rather than filing them.
- Bugs, water or corrosion inside? Same answer: replace it. HomeAdvisor puts a new pressure switch at $120 to $175 installed.
Some people tap the switch cover with a screwdriver handle and the pump kicks on. That's a diagnosis, not a fix. See pressure switch problems.
Step 4: Check the control box (three-wire pumps)
A three-wire submersible has a control box on the wall, usually near the tank. It holds the start capacitor and relay. When either fails, the motor hums or won't start. Look for a scorched smell or a bulging capacitor, but don't open it with power on; capacitors hold a charge.
A tech tests the box and capacitor at the surface. HomeAdvisor puts a start capacitor at $100 to $150 installed and a control box at $200 to $500. Goulds also lists the wrong control box for the motor as a cause of overload trips. Two-wire pumps have no box; their starting parts are in the motor. More on control box and capacitor problems.
Step 5: Let an overheated motor cool
Pump motors have a thermal overload that shuts them off when they get too hot. WAYNE says the overload resets automatically once the motor cools. Goulds lists the causes on a submersible: low voltage, bad connections, a hot control box, debris binding the pump and the pump not being deep enough in the water. If the pump runs a while, quits, and comes back later, one of those is the reason.
Step 6: Check the pressure tank
A waterlogged tank makes the pump start and stop every few seconds, which eventually kills it. Boshart lists rapid switch clicking, short cycling, a fluttering gauge and pulsing pressure as the signs. Knock on the top half of the tank; it should sound hollow. A solid thud means it's full of water. See waterlogged pressure tank.
Step 7: Read the drive's fault code (constant pressure systems)
If you have a variable-speed drive instead of a plain pressure switch, it tells you what's wrong. On Franklin SubDrive units, for example:
| Code | What Franklin says it means |
|---|---|
| F1 | Motor underload, from causes like a damaged pump or plugged screen |
| F2 | Undervoltage, input below 180 VAC |
| F3 | Overcurrent or locked pump |
| F5 | Open phase, little or no current on a motor lead |
| F6 | Short circuit between motor leads |
Franklin says some faults clear on their own, and for others you power off for a few minutes and restart. If a code keeps coming back, it needs a pro. Other brands use different codes, so check your drive's manual.
Step 8: If the pump runs but water doesn't come
This is where the problem moves down the well.
- Jet pump: WAYNE says to check priming first by removing the prime plug. After that, look at suction leaks, a clogged or stuck foot valve, and a water level below the pump's reach. See how to prime a well pump.
- Submersible: Goulds lists a faulty check valve, an air-bound pump, debris binding the pump, excess gas in the well and excessive pump wear. Goulds suggests starting and stopping the pump several times to clear an air-bound pump. Beyond that, it's a pull.
- Low well: Water that comes back after a rest points to the well, not the pump. See no water from your well.
When to call a pro
Call a licensed well contractor once you're past the breaker, switch and tank, or any time the breaker trips twice, the motor hums without starting, or the pump runs without moving water. Those need meter readings at the control box or pressure switch, and possibly pulling the pump.
HomeAdvisor's average well pump repair is $974, with most between $373 and $1,624. A house call usually runs $100 to $150. If the pump itself is gone, HomeGuide puts a submersible replacement at $1,000 to $2,500 installed. See well pump repair for what's worth fixing.
Brand-specific troubleshooting for Goulds, Franklin, Red Lion, Flotec or Sta-Rite pumps lives in the installation manual for your model. Use the steps here to narrow it down, then check that manual's troubleshooting table. The model number on the motor label or control box is what a contractor will ask for.
FAQ
Why is my submersible pump not working?
The usual causes are a tripped breaker, a failed pressure switch, a bad control box or capacitor on a three-wire pump, a tripped thermal overload, or a waterlogged tank. Goulds also lists damaged cable, a bad splice and a worn pump for submersibles. Check the above-ground parts first; the rest needs the pump pulled.
Why won't my well pump turn on?
Common reasons are no power reaching it, a faulty pressure switch, or a low-pressure cutoff that has tripped. Reset the breaker once, check the switch with the power off, and lift the cutoff lever if your switch has one.
Why is my well pump running but not pumping water?
On a jet pump, check the prime first, then look for a suction leak or a stuck foot valve. A submersible may have a leaking check valve, be air-bound, be worn out, or be sitting above a dropping water level. Turn it off before it overheats.
Can I troubleshoot a well pump myself?
You can safely check the breaker, look inside the pressure switch with the power off, reset a low-pressure cutoff, and test the tank's air charge. Testing voltage, amps and capacitors on live circuits, or pulling a submersible, is a job for a licensed pro.
Sources
- WAYNE Water SystemsSWS Series Shallow Well Pump Operating Manual (opens in a new tab)
- Goulds Pumps (ITT)IM096: 4" Submersible Pumps Installation and Operation Instructions (opens in a new tab)
- Franklin ElectricSubDrive and MonoDrive FAQs (opens in a new tab)
- Boshart IndustriesTrouble Shooting: My Water Flow Stops Before My Pump Starts (opens in a new tab)
- Boshart IndustriesHow can I tell if my pressure tank is waterlogged? (opens in a new tab)
- HomeAdvisorHow Much Does Well Pump Repair Cost? (opens in a new tab)
- HomeGuideHow Much Does a Well Pump Cost To Replace or Install? (opens in a new tab)