How to Replace a Well Pressure Switch
To replace a well pressure switch, kill the power, drain the pressure, label the wires, unscrew the old switch, clean or replace the small pipe it sits on, and install a new switch with the same pressure range and electrical rating, wired the same way. It's an easy afternoon job if you're comfortable with basic pump-circuit wiring, and a quick service call if you're not.
Before you buy: is it really the switch?
A lot of "bad switches" are a clogged inlet. Boshart says the tube or 1/4-inch nipple that feeds the switch diaphragm can get blocked with sediment, iron or rust, and a switch that starts when you tap it is a classic sign. Replacing the nipple is the fix Boshart recommends, and you'll do that during a switch swap anyway.
Boshart names a linkage worn from years of use as one real switch failure. Burned or welded contacts, a cracked base or a diaphragm leaking water into the box also mean a new switch. Pitted contacts alone are normal wear, and Boshart says not to sand, file or chemically clean them. If you're not sure, our pressure switch problems page helps you narrow it down.
Match the new switch to the old one
Read the label inside the old switch cover and buy a switch that matches on:
- Pressure range. Common ranges include 30-50, 40-60, 50-70 and 60-80 psi. Stay with what you have unless you've decided to change it.
- Motor rating. The switch has to be rated for your pump's horsepower and voltage. Boshart ties its switches' pump ratings to horsepower and voltage.
- Standard or low-pressure cutoff. If the old one has a lever, decide whether you want the lockout again. Our low-pressure cutoff switch page explains the trade-off.
- Connection. Boshart's switches use a 1/4-18 female pipe thread, which is the usual size.
If only the contacts are worn on a Square D Pumptrol, the maker sells contact replacement kits that include a new diaphragm: 9998PC241 for FSG and FSW switches, 9998PC242 for FYG and FYW. Most homeowners just buy the whole switch.
Tools and parts
- New pressure switch
- New 1/4-inch brass nipple or tube, plus any tee fitting that's corroded
- Thread sealant tape or pipe dope rated for potable water
- Screwdrivers and a 3/8-inch nut driver for the adjustment nuts
- Two adjustable wrenches
- Non-contact voltage tester or multimeter
- Tire pressure gauge for the tank's air valve
- Phone camera for the wiring photo
Step by step
Turn off the pump breaker
Take the switch cover off and test every wire for voltage. Don't trust the label on the breaker.
Photograph the wiring
Most switches have line terminals where power comes in and load terminals to the pump, plus a ground screw. Markings vary by maker. Your photo is your wiring diagram.
Drain the pressure
Amtrol's tank instructions say to turn off the pump power and release all water pressure in the tank and system before service. Open a faucet near the tank and run it until the gauge reads zero.
Disconnect the wires
Loosen the terminal screws, pull the wires and conduit connector out of the switch, and keep the ends apart.
Unscrew the old switch
Hold the fitting below it with one wrench and turn the switch with the other, so you don't twist the tank tee.
Replace the nipple
Look into the old one. If it's packed with rust or sediment, you've found part of your problem. Put in a new nipple with sealant on the threads.
Check the tank pre-charge
With the system drained, read the tank's air valve. Set it to 2 psi below the new switch's cut-in, the setting Boshart and Amtrol both give. Amtrol's manual says only licensed professionals should check or adjust tank pre-charge, so hand this step off if you're unsure.
Thread on the new switch
Snug it by the base, not the cover, and stop with the terminals facing where the wires come in.
Wire it the same way
Line to line, load to load, ground to the green screw. Schneider specifies 15 to 20 lb-in on the terminal and ground screws. Tug each wire after you tighten it.
Close it up and restore power
Cover on first. Then turn the breaker on and let the pump fill the tank.
Test it
Run a faucet and note where the pump starts, then close it and note where it stops. Schneider says to check operation several times after any adjustment. If you need to move the numbers, see how to adjust a well pump pressure switch.
A new low-pressure cutoff switch won't start on its own the first time. Its contacts ship open, so hold the lever at Start until the pump builds pressure.
Mistakes to avoid
- Reusing a crusty nipple. It's the cheapest part of the job and often the actual cause.
- Swapping the line and load wires. The switch still works, but the terminals marked as load stay live with the contacts open. Wire it to the markings.
- Buying a switch rated below your pump. Undersized contacts burn up fast.
- Skipping the tank check. A wrong air charge will short cycle the pump and kill the new switch too.
- Leaving conduit openings unsealed. Boshart warns that bugs and debris getting into the switch create a fire hazard.
When it's a pro job
Hire a licensed electrician or well contractor if you're not comfortable proving a pump circuit dead, if the wiring is aluminum or scorched, or if the pump still won't build pressure with a new switch. HomeGuide puts a pressure switch replacement at $150 to $200 installed, which is cheap insurance against a wiring mistake.
FAQ
How do I wire a well pressure switch?
Power from the breaker goes to the line terminals, the pump wires go to the load terminals, and the ground goes to the ground screw. Copy the old switch exactly from your photo. If the labels on your new switch differ, follow the diagram printed inside its cover.
Can I replace a pressure switch myself?
Yes, if you can safely shut off and verify a dead pump circuit. The plumbing side is a single threaded fitting. If either part makes you nervous, a pro does it quickly.
Should I replace the pressure tank at the same time?
Only if it's failing. Check the tank's air charge while the system is drained. If water comes out of the air valve, the bladder has failed and the tank needs replacing, which our well pressure tank replacement guide covers.
Why won't my new pressure switch turn on?
Check the wiring, the breaker and the inlet nipple first. A new low-pressure cutoff switch needs its lever held at Start for the first fill. Boshart notes that a brand-new standard switch that never works may simply be defective.
Sources
- Telemecanique Sensors (Schneider Electric)Pumptrol Pressure Switch Instruction Sheet 65013-005-39 (opens in a new tab)
- Boshart IndustriesWhy won't my pressure switch turn on? (opens in a new tab)
- Boshart IndustriesHow do I adjust the CUT-IN and CUT-OUT settings of a pressure switch? (opens in a new tab)
- Boshart IndustriesPS02MD Medium Duty Pressure Switches (opens in a new tab)
- AMTROLWell-X-Trol Residential Pre-Pressurized Well Tanks Installation and Operation Instructions (opens in a new tab)
- HomeGuideHow Much Does Well Pump Repair Cost? (opens in a new tab)
- Boshart IndustriesIs my low pressure cut-off switch defective? The contacts are open on my new switch (opens in a new tab)