Well Foot Valve and Check Valve Problems

Short answer

A well foot valve is a one-way valve with a strainer at the bottom of a jet pump's suction pipe, and its only job is to keep water in that pipe when the pump shuts off. When it leaks, water drains back down the well, so the pump loses prime, runs without delivering water, or cycles when no tap is open. Flotec's jet pump manual lists all three as foot valve faults.

Check valves do the same job elsewhere in the system. Submersible wells use check valves in the drop pipe instead of a foot valve, and those failures mean pulling the pump.

Foot valve vs check valve

They're both one-way valves. The difference is where they sit.

  • Foot valve. At the bottom of the suction pipe in a dug or cased well, with a strainer on it. On a deep-well jet setup, it sits below the jet in the well.
  • Check valve. Anywhere in a line where water must flow only one way. Flotec's shallow-well pump has one built in, and driven-point wells use a check valve near the well instead of a foot valve.
  • Submersible check valve. Threaded into the drop pipe above the pump, down in the casing. Your pump's manual sets how many and where.

If you have a jet pump in the basement or a well house, you probably have a foot valve. If the pump is down the well and you only see a pipe and wire at the top, you have check valves.

Signs a foot valve or check valve is failing

Flotec's troubleshooting table matches symptoms to valve problems:

What you seeLikely valve causeFix the manual gives
Pump runs but delivers no waterLeaking foot valveReplace the foot valve
Pump runs but delivers no waterCheck or foot valve stuck closedReplace the valve
Pump runs but delivers no waterFoot valve or strainer buried in sand or mudRaise it above the well bottom
Pump cycles too oftenFoot valve leaksReplace the foot valve
Air spurts from faucetsLeak on the suction sideCheck the suction pipe and joints

Source: Flotec (Pentair), FP2521 Shallow Well Jet Pump/Tank System Owner's Manual

The classic sign is a pump that has to be reprimed every morning. Flotec says that with working foot and check valves and no suction leaks, a jet pump shouldn't need repriming in normal service.

How to test it

You don't need special tools for the first check.

  1. Let the pump fill the tank and shut off.

  2. Close the valve between the tank and the house, or make sure nobody uses water.

  3. Watch the pressure gauge for an hour.

Tap a number to tick off a step. 0 of 3 done.

If the pressure falls with no water being used, water is going somewhere. On a jet pump, that's usually backflow through the foot valve or a suction-line leak. On a submersible, it's a check valve, a drop-pipe leak or a pitless adapter seal. Rule out a running toilet or a leaking outdoor spigot first.

Tools and parts

  • New foot valve with strainer, the same pipe size as the suction line
  • PVC or poly pipe, fittings and clamps as needed
  • Pipe wrenches and thread sealant
  • A bucket and water for repriming

Replacing a foot valve on a shallow well

On a shallow jet pump with an accessible well, this is a manageable owner job.

  1. Power off

    Shut off the pump breaker and drain pressure at a faucet.

  2. Pull the suction pipe

    Lift the pipe out of the well. Have a helper if it's long, because a wet pipe full of water is heavy.

  3. Inspect

    Look at the strainer and valve. Sand, a cracked body or a flapper that won't seat all mean replace.

  4. Check the new valve

    Flotec says to confirm the foot valve moves freely before installing it.

  5. Set the depth

    Flotec puts the foot valve and strainer 5 to 10 feet below the lowest level the water drops to while pumping, and 5 to 10 feet above the well bottom.

  6. Seal every joint

    Any air leak on the suction side stops the pump from priming.

  7. Reprime

    Fill the pump through the priming tee or plug. Flotec says water should arrive within 1 to 2 minutes of starting. If it doesn't, stop, refill and try again. Our how to prime a well pump page has the details.

Tap a number to tick off a step. 0 of 7 done.

Mistakes to avoid

  • Setting the valve on the bottom. It pulls in sand and clogs.
  • Ignoring suction lift. At sea level, Flotec limits total lift from the pumping water level to the pump at 20 feet, and about 1 foot less per 1,000 feet of elevation. A new foot valve won't fix a water level that's dropped too low for a shallow jet pump.
  • Chasing the valve when it's a joint. A cracked fitting on the suction line gives the same lost-prime symptom.
  • Repriming over and over. Each dry start is hard on the pump. Find the leak.

When it's a pro job

Call a well contractor when the check valve is down the well on a submersible, when the suction line runs to a deep-well jet, or when the pipe won't come out. Pulling a submersible pump is a two-person job with a lifting rig. While the pump is out, it's the time to replace the check valve too. See well pump replacement.

HomeGuide puts a check valve replacement at $150 to $200 and a foot valve at $150 to $400, both with labor.

FAQ

Where is the check valve on a well pump?

On a jet pump, it's often built into the pump or the suction line near the well. On a submersible, it's on the drop pipe just above the pump, plus sometimes one more near the pressure tank. Look for a short brass or plastic fitting with a flow arrow.

Should you put a check valve on a well pump?

Yes. Without a foot valve or check valve, the suction line loses its water every time the pump stops. Follow the pump manual for where it goes and how many.

How much does a check valve cost for a water pump?

HomeGuide lists $150 to $200 installed for a check valve and $150 to $400 for a foot valve. A submersible job costs more because the pump has to come up.

How do I unstick a well check valve?

Usually you don't. A valve stuck closed gets replaced, per Flotec's troubleshooting table. Sand and scale are the usual causes, so check the strainer and well bottom too.