How to Light a Water Heater Pilot Light

Short answer

To light the pilot on a gas water heater, turn the gas control knob to OFF and wait for any gas to clear, then set it to PILOT, hold it in, and click the igniter until the flame catches. Keep holding for a bit after it lights, release slowly, and turn the knob to ON.

The exact steps are printed on the lighting label on your tank. Follow that label first. What's below is the general method, using A.O. Smith's published procedure as the reference, plus what to do when it doesn't work.

Before you start

Check three things:

  1. Smell around the bottom of the heater. A rotten-egg smell means stop and call.

  2. Make sure the manual gas valve on the supply line to the heater is open. A.O. Smith's manual makes that step one.

  3. Find out what kind of ignition you have. Most standing-pilot heaters have a push-button igniter next to the gas control. Older ones need a long lighter. Some newer heaters have no pilot at all and light electronically, and those don't get relit by hand.

Tap a number to tick off a step. 0 of 3 done.

You'll need a flashlight. If there's no igniter button, you'll also need a long-reach lighter.

Step by step: standing pilot with a push-button igniter

  1. Turn the gas control knob to OFF

    Then wait. A.O. Smith says to wait at least 10 minutes so built-up gas can disperse before you try to light it. Don't skip this.

  2. Set the knob to PILOT

    Push the knob in fully and hold it. A.O. Smith notes the knob should move about 1/4 inch when pressed.

  3. Click the igniter

    While holding the knob in, press the igniter button about once per second for up to 90 seconds. Watch through the viewport for the flame.

  4. Keep holding after it lights

    The thermocouple needs heat before it can hold the gas valve open on its own. Most labels tell you to keep holding the knob for a while after the flame appears. Use the time on your label.

  5. Release slowly and check

    Let go of the knob and confirm the pilot stays lit. On heaters with a status light, A.O. Smith says the light should start flashing; on the ProMax a lit pilot flashes once every three seconds.

  6. Turn the knob to ON or your temperature setting

    You should hear the main burner light with a soft whoosh. A.O. Smith's HOT mark is about 120°F, which reduces scald risk.

Tap a number to tick off a step. 0 of 6 done.

If the status light doesn't start flashing after 90 seconds, release the knob and wait 10 minutes before trying again. The manual says to repeat that at least two more times. After three failed tries, turn the knob to OFF and call a qualified person.

Older heaters with no igniter button

The steps are the same, except you light the pilot with a long lighter. A.O. Smith's FAQ says to use a long lighter while holding the knob in. Remove the outer and inner access covers, find the pilot burner (it's the small tube next to the thermocouple tip, not the big round main burner), and hold the flame to it while you keep the knob pressed.

Put both covers back before you leave. Running a heater with the burner door off messes up the airflow and can let flames roll out.

Sealed-combustion heaters

Most gas heaters built in the last couple of decades have a sealed combustion chamber with flame-arrestor protection, so you can't stick a lighter in there. The ProMax manual, for example, describes a Flammable Vapor Ignition Resistance (FVIR) system. On these, the igniter button is the only way to light it. If the igniter doesn't spark, see water heater igniter not working rather than forcing the issue.

Electronic ignition models

Some heaters have no standing pilot. They use a hot surface igniter that comes on only when the heater needs to fire. There's nothing to light by hand. If one of these won't fire, check that it has power and the gas is on, then call a pro. A.O. Smith's guide says there's no fallback if the electronic ignition fails.

If it won't light or won't stay lit

These are the usual reasons:

  • It lights but goes out when you let go. A common cause is the thermocouple or thermopile, the sensor that powers the pilot safety valve. Test it before you replace it: how to test a water heater thermocouple.
  • No spark. Check the igniter wire connection at the igniter. A.O. Smith says to make sure it's firmly inserted.
  • Spark but no flame. Gas isn't getting to the pilot. Check the supply valve again. A kink or clog in the gas tubing is another cause.
  • Goes out after a few hours or days. Drafts or not enough combustion air. A.O. Smith's troubleshooting guide adds that blocked air screens or filters restrict combustion air. Clean the filter at the base of the heater and see whether the area around it is cluttered.
  • Electronic lockout. After several failed attempts, some controls lock out to prevent gas buildup. Wait and follow the manual.

Our full troubleshooting pages are pilot light won't light and pilot light won't stay lit.

Mistakes to avoid

  • Skipping the wait after turning the knob to OFF. That wait is what keeps a pocket of gas from going off when you light it.
  • Holding the knob for a second and letting go. The thermocouple hasn't warmed up yet, so the pilot drops out and people assume it's broken.
  • Turning the knob straight to ON before the pilot is lit.
  • Leaving the burner access covers off.
  • Relighting over and over when it keeps going out. Once or twice is troubleshooting. Ten times is a gas appliance with a problem.

When to call a pro

Call a plumber or gas technician if the pilot won't light after three tries, keeps going out after you've relit it, burns yellow and lazy, or if you see scorch marks around the burner door. HomeGuide puts pilot light replacement at $50 to $200, and thermocouple replacement at $100 to $325. A bad gas control valve is the expensive one, at $150 to $550, and A.O. Smith says that part should be replaced by a professional. For more on that, see water heater gas control valve problems.

FAQ

Can I light my water heater pilot light myself?

Yes, if there's no smell of gas and you follow the lighting label on the tank. The job takes a few minutes plus the wait time. If it doesn't light after three tries, A.O. Smith says to turn the control off and call a qualified person.

How do I relight a pilot light with an igniter?

Set the knob to PILOT, press and hold it, and click the igniter roughly once per second until the flame catches. Keep holding, then release slowly and turn the knob to ON.

How do I light a Honeywell gas water heater?

Many heaters use a Honeywell or Resideo gas control, but the lighting steps are set by the water heater maker and printed on the tank label. The same sequence applies: OFF and wait, PILOT and hold, ignite, release, ON.

Why is my water heater not heating after I lit the pilot?

Check that you turned the knob from PILOT to ON or a temperature setting. If the pilot is lit and the burner still won't come on, the gas control valve may not be opening or the burner isn't getting air. That's a service call.