Gas Water Heater Installation
A proper installation of a gas water heater covers five things: a safe location with enough combustion air, a vent that actually drafts, a leak-tested gas connection with a shutoff and sediment trap, water lines with a correctly piped relief valve, and a full tank before the burner ever lights. It's a job most homeowners should hand to a licensed plumber, because a small mistake in the gas or vent work can fill a house with gas or carbon monoxide.
Is it hard to install a gas hot water heater?
The plumbing half isn't. The gas and vent half is where skill matters. A.O. Smith strongly recommends a professional installer for its gas tanks, citing venting, the fuel line and removing the old unit. Most areas require a permit, and A.O. Smith's manual says to follow local and state codes, or NFPA 54 (the National Fuel Gas Code) where none exist, and to have a code official inspect the work. Check with your local building department before you start.
Location and combustion air
A.O. Smith's gas tank manual sets out the basics:
- Indoors, upright, in a spot that won't freeze, with at least 24 inches of clearance in front.
- Not in a bathroom, bedroom or a normally closed occupied room.
- No gasoline or other flammable liquids or vapors stored nearby.
- In a garage, a vehicle stop so a car can't hit it.
Combustion air is the part people skip. The manual calls for 50 cubic feet of room volume per 1,000 BTU per hour of total input from every gas appliance in the space. A small closet with a furnace and a water heater often fails that test, and then the manual calls for two permanent outside air openings.
Venting: atmospheric, power vent and direct vent
An atmospheric vent relies on hot exhaust rising up a vent pipe. A.O. Smith's manual recommends at least 12 inches of vertical pipe off the draft hood before any elbow, and requires an upward slope of at least 1/4 inch per foot on horizontal runs. Single-wall pipe needs 6 inches of clearance from combustibles. After installation, the manual has you pass a newly extinguished match near the draft hood opening after 5 minutes of burner operation and confirm the smoke is steadily drawn in. If it drifts or blows away, the vent isn't drafting, and that's a carbon monoxide problem.
A power vent water heater uses a fan to push exhaust out, usually sideways through a wall, which frees you from needing a chimney. The fan needs electricity, and Fixr says adding a power vent and its electrical connection can add $300 to $1,000 to the job. HomeGuide puts power vent models at $350 to $500 more than direct vent models. Propane and natural gas power vent models work the same way; the gas valve and orifices are set for one fuel or the other.
Don't connect a power-vented appliance into a shared atmospheric vent. A.O. Smith's manual prohibits common venting with a power-vented appliance.
Tools and parts
- Pipe wrenches, adjustable wrenches, tubing cutter
- Gas-rated pipe dope or yellow gas tape
- A manual gas shutoff valve, a sediment trap and a ground joint union
- Vent connector pipe and fittings matching the heater's flue
- Copper or CPVC for the T&P discharge
- Drain pan, expansion tank if needed, water connectors
- Soapy water in a spray bottle for leak checks
How a gas water heater install goes
Turn off the gas at the heater's shutoff and the cold water supply. Open a hot tap.
Drain the old tank, then disconnect the gas line, vent connector and water lines.
Set the new heater in its pan, level, with the required clearances.
Connect the water lines, cold to inlet and hot to outlet, and install the expansion tank if your system needs one. See water heater expansion tanks.
Pipe the T&P relief valve: at least 3/4-inch inside diameter, sloped, ending no more than six inches above a floor drain or outside, never into the pan and never capped.
Build the gas connection: a readily accessible manual shutoff, a sediment trap at least 3 inches long, and a union between the shutoff and the heater's gas valve.
Connect the vent and check slope, clearances and joints.
Fill the tank completely with water before lighting the pilot, and run a hot faucet for three minutes to purge air.
Turn the gas on and brush every joint with a solution of one part dish soap to 15 parts water. Bubbles mean a leak. Tighten and recheck.
Light the pilot following the label on the tank. Our how to light a water heater pilot light guide walks through it.
Run the burner and do the draft test. Set the thermostat. A.O. Smith's "HOT" setting is about 120°F.
Mistakes to avoid
- Skipping the sediment trap. Debris and moisture in the gas line end up in the gas control valve.
- A flat or downhill vent connector. Exhaust stalls, spills at the draft hood and comes back into the room.
- Lighting a half-empty tank. The manual says to fill it completely first.
- Running the relief line into the drain pan.
- Testing for leaks with a flame. Use soapy water or a gas leak detector.
Cost and when you need extra work
Fixr's installed range for a natural gas tank is $700 to $2,700. Adders show up fast: HomeGuide lists a gas line upgrade at $350 to $2,000, first-time venting at $500 to $1,500, and replacing existing venting at $100 to $600. A permit typically runs $50 to $200. Going from electric to gas costs $400 to $2,000 or more. For the full breakdown, see water heater installation cost.
FAQ
How do I connect a gas water heater?
Run the supply through a manual shutoff, a sediment trap and a union to the heater's gas control valve, using gas-rated thread sealant. Then turn the gas on and leak-check every joint with soapy water before lighting the pilot. If any of that is unfamiliar, this is where to call a licensed plumber.
How do I replace a gas water heater?
Shut off gas and water, drain and disconnect the old tank, set the new one, then reconnect water, vent and gas in that order. Fill the tank before lighting it. Our water heater replacement page covers permits and haul-away.
How does a power vent water heater work?
A fan on top of the heater pushes exhaust out through a vent pipe, usually through a side wall, instead of relying on hot air rising up a chimney. The fan needs an electrical connection, so a power vent heater won't run during a power outage.
How long should a gas water heater take to heat up?
Fixr puts gas units at closer to 30 to 40 minutes to heat up, compared with up to 60 minutes for electric. A brand-new tank starting from cold water can take longer the first time.
Sources
- A. O. SmithProLine Standard Atmospheric Vent Gas Water Heater Manual (100263112) (opens in a new tab)
- HomeGuideHow Much Does Water Heater Installation Cost? (2026) (opens in a new tab)
- FixrWater Heater Installation Cost (opens in a new tab)
- A. O. SmithGas Water Heaters (opens in a new tab)
- A. O. SmithGas Tank Water Heaters (opens in a new tab)